What is the default arc flash boundary?

NFPA 70E establishes the default arc flash boundary at 4 feet for low voltage (< 600V) systems where the total fault exposure is less than 5000 amperes-seconds (fault current in amperes multiplied by the upstream device clearing time in seconds).

What causes arc flash?

An arc flash causes a very loud sound created by quickly-moving air, or a sound wave, that can reach 140 decibels at a distance of just two feet. Standard earplugs typically protect only up to 105 decibels, and you can go deaf from the intense arc flash sound.

How long does an arc flash last?

Flash burns are like sunburn in the eye and can affect both your eyes. Your cornea can repair itself in one to two days, and usually heals without leaving a scar. However, if the flash burn is not treated, an infection may start.

LOTO – Lockout Tagout

LOTO – Lockout Tagout is the Physical restraint of DeviceĀ as Hazardous Energy source, While doing Servicing/Maintenance.

What is Energy Control Program ?

Energy Control Program makes sure that Equipment is isolated from energy source and made inoperative before planned Service/Maintenance.

Fire Classification

Fire Classification basis Material Involved in Fire and Essential Extinguiser Effect required for Fire Suppression.

How to do Hot Dip Galvanization ?

Galvanization is the process of applying Zinc coating on Steel to prevent Corrosion. In Hot dip Galvanization, Fabrication is submerged in Molten Zinc.

Arc Flash Hazard Risk Category

HRC – Hazard Risk Category is determined by amount of Incident Energy released upto defined boundary from the source of Arc Flash Point.

Degree of Burn

Degree of Burn is the level of depth of Burn effect on the human skin up to bones.

What causes Arc Flash?

Arc flash occurs when electrical current becomes uncontrolled, results in release of energy that ionizes air, releasing enormous heat, light, sound.

Burns caused by Arc Flash

Degree of severity of burns is based on size and depth of the burn on human body. Fire, steam, Radiation, chemicals, Electric Arc, can cause burns.

What is Arc Blast ?

Arc Blast is the supersonic shockwave produced when the uncontrolled Arc vaporizes the metal conductors and expanding Plasma.

What is Arc Flash assessment?

Arc Flash assessment determines the degree to which worker may be exposed to potential Arc Flash Hazards and what kind of PPE is required.

When can Arc Flash occur ?

Arc Flash occurs when insulation or isolation between electrified conductors is breached or can no longer withstand the applied voltage.

Factors affecting short circuit fault

Short-Circuit fault allows the current to flow through unintended path with very low impedance, which results into excessive current flow through the path.

How to do Powder Coating ?

In Powder coating process, CRCA surface is given Anti Corrosive Surface treatment, then Epoxy Powder is applied, melted and hardened.

What is I2t – Let through Energy ?

I2t – Let through Energy is available thermal energy resulting from Current Flow during circuit opening in Fuse, MCCB, MCB.Unit is A2S (Ampere2 Second)

Let Through Energy

I2t – Let through Energy is available thermal energy resulting from Current Flow during circuit opening. I2t (of circuit breaker) < K2S2 (of cable)

Methods of Heat Transfer

Heat is a flow of energy from higher temperature object to lower temperature object. Heat transfer continues until two objects reaches thermal equilibrium.

What is Electrical Insulating Materials ?

Nonconducting material that provides electric isolation of two parts at different voltages.
It must have an electrical resistivity and a dielectric strength sufficiently high for the given application.
The secondary requirements relate to thermal and mechanical properties.