Comparative Tracking Index (CTI) for Insulating Material group – IEC 60112

CTI is max voltage which material can withstands 50 water drops without without formation of conductive path.

CTI is max voltage which material can withstands 50 drops of water contaminated with ammonium chloride etc, without tracking, i.e without formation of conductive path, due to Humidity, Contamination or Electrical stress.

Material
Group
Comparative Tracking Index
(CTI) – in Volts
Insulating Material
group – I
600V and above
Insulating Material
group – II
400V to 599V
Insulating Material
group – IIIa
175V to 399V
Insulating Material
group – IIIb
100V to 174V
Comparative Tracking Index (CTI) – Material group – IEC 60112

AC Utilization Categories IEC 60947

Utilization Categories indicate the type of Load and Duty Cycle of the load basis which selection of Switchgear should be done for the intended application.